Viteg Cooling Tower monitoring apps is a real time supervision for building central condensing water system and make up water supply system under on-line control, including cooling towers, condensing water pumps, air- cooled chillers, and water-cooled chillers, while equipment fails, Viteg will notify users immediately. 7 days system log for users trace the whole operating status, vetting data charts to analyze system performance, set the operating time of the condensing system, and remotely control the condensing system in emergency situations.Real-time monitoring functionAccording to system schematic diagram, users can quickly, accurately and clearly understand the real-time operating status of the system. 3 kinds of application program are available which included cooling tower system, air-cooled chiller system and water-cooled chiller system for users select. Find major device data, users can click on the schematic to vetting the information, example of the equipment status. Furthermore, of detailed equipment information, apps provided the listed data table for reference.System trend log 7 days system operating trend log is available for users assess, the system trend log records different equipment’s detailed data and also classified into 3 kinds of log sheet i.e., actuation, alerts and alarms according to the data content. Users select equipment or type of data log by sorting tools for fast review.Graph analysisDaily performance chart and annual performance chart are designed for statistics. The daily performance chart provides the operating status of the condensing system equipment, user can know the on-off status and 24-hour operating time of the condensing equipment through the chart, and a total performance of the condensing system will be summarized on the chart. The annual performance chart provides 3 types of charts, one is daily system electricity consumption and condensing system cooling capacity, second is Coefficient of performance (COP) and average COP, third is outdoor temperature and indoor temperature condition record.Setting of operation hourThrough the apps user can setting or confirm the operating hours of the condensing system from Monday to Sunday easily.remote controlUnder emergency situation, user can remotely control the condensing system and the make-up water system in an emergency mode. Using override control mode through the apps, user can operate the condensing system and make-up water system to running. In condensing override mode, the user needs to select one set of the condensing system and run it at the minimum cooling capacity. In make-up water system override mode, the user needs to select the override time and select the make-up water pump to run.contact usSend us your request or concern and well get you the help you need.Email :
[email protected]